Rife1.Com


Rife Technology Systems Research



color dot



ALTERNATIVE HEALTH BIO-ELECTROMAGNETIC
ELLIPTICAL/CIRCULAR POLARIZED ANTENNA
ARRAY FOR EXPERIMENTAL USE AT 27.120 MHz


Bio-Electromagnetic Field Concentrating Antenna.  May Possibly
Be Used For Personal Alternative Health Care Energy Research
Into Experimental Modulated Radio Frequency Rife Technology
 

| CLICK HERE FOR PICTURES |



| Description |
| Disclaimer |
| Operational Power |
| Why No Plasma Tubes? |
| Operation and Safety Notes |
| Technical Design Notes |
| Personal Notes |

| Go Back to the Index |


Description:
This antenna array is designed to focus radio frequency electromagnetic energy into a concentrated area with a very even distribution of field intensity. It does not require the use of an external antenna tuner. This compact broadband antenna array consists of two individual 26 inch diameter magnetic loop antenna elements. When operated as designed the combination of the two active antenna elements develop a circular or elliptically polarized wave front. This elliptically polarized rotating wave front contains both vertical and horizontal components as well as every possible diagonal polarization angle in between. This ensures thorough and even application of modulated radio frequency energy regardless of the antenna or target orientation. It exhibits a characteristic operating impedance of 50 ohms and may be connected to any standard CB or ham radio transmitter. It is tuned for broadband operation with very low SWR (standing wave ratio) in the FCC designated ISM (Industrial Scientific Medical) frequency band allocated at 27.120 MHz +- 160 KHz.

| Go Back to the Top |   | Go Back to the Index |



Disclaimer:
You may make the personal choice to use this antenna to facilitate personal research and experimentation utilizing the application of Amplitude Modulated Radio Frequency Rife Technology. I make no claims  regarding the efficacy of this antenna for any possible medical therapy or treatment for any particular disease. The FDA has not tested or approved this antenna for any medical treatment or therapy. This is not necessarily a medical device per se, it is an antenna array designed to develop concentrated 11 meter wavelength radio frequency electromagnetic field energy with an accurately controlled elliptically polarized distribution pattern. Use of this antenna for any purpose whatsoever is entirely at your own risk and is experimental. It is simply an antenna, not a medical device, nor an accessory to any medical device. If you have medical problems go see a medical doctor or medical practitioner, I am neither. This device is not FDA restricted. I do not endorse or warrant the accuracy of any information found on other web pages linked to from this web site.

| Go Back to the Top |   | Go Back to the Index |



Operational Power Recommendations:
I do not suggest or recommend use of this antenna at the high power levels found in experimental Rife technology Rife-Bare units. Unlike plasma tubes this antenna is very electrically efficient with low energy losses. I do not recommend the use of a high power linear amplifier. I personally would not sit anywhere near this antenna running at anything over ten or at most twenty watts under any circumstances. My own successful personal experimentation to date has been at operating power levels of four watts. I have tested this antenna array (at a distance) with a power level of 50 watts. At 50 watts of input power the rf transformer magnetic toroid cores in the matching network exhibited a small amount of heating and stable SWR indicating that there were no core saturation loss problems to be expected during operation at or below the designed power limit of twenty watts.

| Go Back to the Top |   | Go Back to the Index |



Why No Plasma Tubes?
Plasma tubes look really cool, but I do not believe that they are necessary for the construction of modern functionally effective Rife Technology systems. They are very difficult and expensive to drive safely with RF as well. Plasma tubes can create all kinds of radiation, radio interference, electromagnetic compatibility and FCC regulatory problems. The use of a plasma tube as an antenna and mixer in the original Rife Ray devices simply facilitated the mixing and distribution of modulated radio frequency waves with randomized harmonic frequencies and polarization. Rife's personal notes indicate that there was nothing unique in his use of gas plasma tubes. It just was a convenient and commonly available device in the 1920's and 30's. Back then most everything electronic was done with tubes of some sort. The use of magnetic loop type antenna elements instead reduces any possible risk of RF burns that may be associated with the high RF voltages and power levels required to ionize a gas plasma tube. A magnetic loop antenna element with a diameter of a significant proportion of the operational wavelength is a much more efficient radiating element than a small plasma tube is. I do not disparage the potential therapeutic efficacy of the use of a gas plasma tube as a radiating element. I am actively investigating the development of gas plasma units as well. Plasma tubes are just not a very efficient antenna at an 11 Meter wavelength. I simply chose this magnetic loop antenna design as a convenient conceptual starting point for my own practical experimentation. It is relatively safe, efficient, stable, reliable, repeatable and easily constructed.

| Go Back to the Top |   | Go Back to the Index |



Operation and Safety Notes:
This antenna array should be operated a reasonable distance away (several feet) from any large conductive metal objects. Nearby objects such as refrigerators, appliances, metal chairs, heating and cooling ducts can adversely affect operational SWR and distort the electromagnetic field. All personally worn metal objects should be removed as well during exposure to avoid the possible creation of RF hot spots. Watches, glasses, underwires etc. should not be worn during exposure. Persons with embedded medical devices should also avoid exposure altogether as well. Implanted medical devices such as pacemakers, automated insulin pumps and steel plates are not compatible with exposure to electromagnetic radiation fields. If you have any concerns regarding exposure to radio frequency energy similar to the normal operation of high powered 10 Meter ham radio equipment you should discuss them with your own doctor or medical practitioner.

| Go Back to the Top |   | Go Back to the Index |



Technical Design Notes:
Two multiple turn magnetic loop antenna elements are provided each with an approximate diameter of 1/16 wavelength of the designed 11 meter operating wavelength. Both of these elements are designed to transmit simultaneously with nearly equal intensity and are operated with orthogonally opposed polarization. This combination of orthogonal polarization and a 90 degree operational phase shift between the two active antenna elements creates an elliptical radiation pattern characteristic. These antenna elements are wound with large diameter trifilar windings to facilitate broadband frequency operation with very low SWR. A fixed impedance matching network is provided to facilitate connection to standard 50 ohm output impedance radio transmitters.

| Go Back to the Top |   | Go Back to the Index |



Personal Notes:
My own initial first impressions of many so called energy healing technologies were admittedly accompanied with a great measure of skepticism. There is a whole lot of whacko stuff to be found out there. The more research I did, the more patented and FDA approved devices with similar underlying technologies I discovered, and the more I became convinced of the possible effectiveness of some devices utilizing such technology. Enough to convince me to spend the time required to develop experimental methods of application designed to improve consistency and repeatability. This antenna represents much of my present understanding and execution of available experimental Rife technologies and modern electromagnetic field shaping antenna system design. I currently have several other related concepts under development. Why no patents? Unless you have $20 million or so on hand to defend a patent I consider them to be effectively worthless in the current global corporate business environment. First to publish and first to market with the best customer service are the keys to success in my humble opinion. Does it work? Does it help? In my own personal experience I can state anecdotally, yes it works for me and I have found it very helpful. My first personal use of this antenna induced a pretty good herxheimer reaction. Subsequently my overall health has begun to improve greatly while many of my chronic fatigue and other problem symptoms have been reduced significantly. I can not say here what it may or may not do for you without the risk of incurring the immense wrath of the FDA. I do not recommend the use of this antenna for any medical purpose whatsoever. If you choose to do so that is your own personal decision for which you will be ultimately responsible yourself.

| Go Back to the Top |   | Go Back to the Index |





PICTURES

You may click on any picture to enlarge it.
Click on your back button to return here.



Antenna Array Block Diagram

block diagram




Antenna Array and optional antenna stands.

    
block diagram




Experimental Modulated RF Rife System Block Diagram.

block diagram




If you already have a Rife Crane tone generator you can
now easily upgrade to a Modulated RF Rife System.
All you need add is this Antenna, a Transmit Interface
and an ordinary CB or ham radio transmitter.

block diagram




Actual SWR, Power and Modulation measurements as shown
in my own living room under normal operating conditions.


block diagram

| Go Back to the Top |   | Go Back to the Index |







animated cube 2 gif color line   color dot   color line  animated cube 1 gif







 

© 2003 - 2005   Steven D. Frahm